Available Options
Options for: Motor Starters & Pump Panels
Description | Option Code |
---|---|
Control Circuit Transformer With Primary & Secondary Protective Fuses | |
208/240/480 – 120V @ 50VA | CT50 |
208/240/480 – 120V @ 100VA | CT100 |
208/240/480 – 120V @ 150VA | CT150 |
208/240/480 – 120V @ 250VA | CT250 |
208/240/480 – 120V @ 500VA | CT500 |
Interposing Relay For separate control voltage input ( ** Specify required Voltage when ordering) | IR-** |
Time Delay Relay ( ** Specify required function when Ordering) Note: This option requires a control circuit transformer | TD-** |
Programmable Time Clock 24 Hour, 7 Day function Note: This option requires a control circuit transformer | TC |
Liquid Level Relay ( ** Specify required function when ordering) Note: This option requires a control circuit transformer | LLR-** |
Indicating Light Specify Function and Lens color when ordering (ie: run/red) | PL-** |
Electronic Programmable Overload Relay Protects 3 Phase Motors against: Overload, Underload, High Voltage, Low Voltage, Loss of Phase, Phase Reversal, Phase & Voltage, Unbal-ance, Rapid Cycling, and Ground Fault | |
Motor Full Load Amps: 2 – 90 Amps | DEOL |
Motor Full Load Amps: 91 – 600 Amps (includes current transformers) | CTEOL |
Phase & Voltage Monitor Protects Three Phase motors against: High Voltage, Low Voltage, Phase Reversal, Loss of Phase, and Unbalance | PMR |
Secondary Surge Arrester Offers a degree of protection against damage due to lightning strikes | LA |
Surge Capacitor Controls surges which are too light or fast for a surge arrester | SC |
Low Suction Cut-Off Option includes a Terminal Block for remote pressure switch, a Red Indicating Light, and a Timing Relay to prevent nuisance tripping Note: This option requires a Control Circuit Transformer | LSC |
High Pressure Shutdown Option includes a Terminal Block for remote pressure switch, a Red Indicating Light, and manual Reset Pushbutton Note: This option requires a Control Circuit Transformer | HPS |
Elapsed Hour Meter Records motor running time in Hours, Non Reset, 99999.9 Hours Note: This option requires a control circuit transformer | ETM |
NEMA Type 4 Steel Enclosure Water & Dust-Tight, Outdoors | N4 |
NEMA Type 4X Stainless Steel Enclosure Water & Dust-Tight, Outdoors, Corrosion-Resistant | N4XS |
NEMA Type 4X Fiberglass-Reinforced Polyester Enclosure Water & Dust-Tight, Outdoors, Corrosion-Resistant | N4XF |
Starter Auxiliary Contacts 1 N/O & 1N/C contacts interlocked with starter | AUX |
Options for: Duplex Booster
Description | Option Code |
---|---|
Low Suction Cut-Off Option includes a terminal block for remote pressure switch, a Red In-dicating Light, and a Timing Relay | LSC |
Low Pressure Alarm Option includes a terminal block for remote pressure switch, a Red In-dicating Light, and a Timing Relay | LSP |
High Pressure Shutdown Option includes a terminal block for remote pressure switch, a Red In-dicating Light, and manual Reset Pushbutton | HPS |
Interposing Relay For use with separate control voltage ( ** Indicate required Voltage when ordering) | IR-** |
Time Delay Relay ( ** Indicate required function when Ordering) | TD-** |
Programmable Time Clock 24 Hour, 7 Day function | TC |
Elapsed Hour Meter 99999.9 Hours, Non Reset Quantity Two | ETM |
Cycle Counter 6 Digits, Non Reset Quantity Two | CC |
Indicating Light ( ** Indicate Lens color and Function when ordering) | PL-** |
Phase & Voltage Monitor Protects 3-Phase motors against: High Voltage, Low Voltage, Phase Reversal, Loss of Phase, and Unbalance | PMR |
Surge/Lightning Arrester | LA |
Surge Capacitor | SC |
Starter Auxiliary Contacts Option includes 1-N.O. & 1-N.C. Auxiliary Dry or Powered Contacts for interfacing with remote loads or monitoring Quantity Two Sets (one per starter) | AUX |
Electronic Programmable Overload Relay, Motor Saver 777 Protects 3-Phase Motors against: Overload, Underload, High Voltage, Low Voltage, Loss of Phase, Phase Reversal, Phase & Voltage Unbal-ance, Rapid Cycling, and Ground Fault Quantity Two
| DEOL |
External Electric Reset Pushbutton for Motor Saver 777 Quantity Two | EOLR |
Deduct for Auto Duplex Alternator | NALT |
Terminal Block 3P, 600V, 30 AMPS (Specify Function) | TB |
Options for: Duplex Lift Station
Description | Option Code |
---|---|
Dead-front Enclosure Construction Tamper-proof design with Swing-out inner door and Lockable outer door | A |
NEMA/UL Type 4 Enclosure Steel, Water & Dust-Tight, Indoor/Outdoor use | B |
NEMA/UL Type 4X Fiberglass-Reinforced Polyester, Water & Dust-Tight, Indoor/Outdoor use, Corrosion-Resistant | C |
NEMA/UL Type 4X 304 Stainless Steel, Water & Dust-Tight, Indoor/Outdoor, Corrosion-Resistant | D |
Anti-Condensation Cabinet Heater 100 Watt, Fan-Driven, with integral adjustable thermostat | E |
Elapsed Hour Meters (2) 99999.9 Hours, Non-Reset, door mounted | F |
Pump Running Indicating Lights (2) Green Lens, door mounted | G |
Auxiliary Contacts (2) 1-N.O./1-N.C. for remote monitoring of pump status | H |
Motor Seal Failure Indicating Light (2) Amber Lens, door mounted – Option requires Moisture Detecting Relay | I |
Moisture Detecting Relays (2) Relay Monitors a Seal Failure condition in the motor. Unless otherwise speci-fied, the standard design will not shut-down pump. | J |
Options for: Simplex Lift Station
Description | Option Code |
---|---|
Dead-front Enclosure Construction Tamper-proof design with Swing-out inner door and Lockable outer door | A |
NEMA/UL Type 4 Enclosure Steel, Water & Dust-Tight, Indoor/Outdoor use | B |
NEMA/UL Type 4X Fiberglass-Reinforced Polyester, Water & Dust-Tight, Indoor/Outdoor use, Corrosion-Resistant | C |
NEMA/UL Type 4X 304 Stainless Steel, Water & Dust-Tight, Indoor/Outdoor, Corrosion-Resistant | D |
Anti-Condensation Cabinet Heater 100 Watt, Fan-Driven, with integral adjustable thermostat | E |
Elapsed Hour Meter 99999.9 Hours, Non-Reset, door mounted | F |
Pump Running Indicating Light Green Lens, door mounted | G |
Auxiliary Contacts 1-N.O./1-N.C. for remote monitoring of pump status | H |
Motor Seal Failure Indicating Light Amber Lens, door mounted – Option requires Moisture Detecting Relay | I |
Moisture Detecting Relay Relay Monitors a Seal Failure condition in the motor. Unless otherwise speci-fied, the standard design will not shut-down pump. | J |
Motor Over-Temperature Shutdown Terminal Block for thermal switch in motor. Motor shutdown with auto reset | K |
Motor Over-Temperature Indicating Light Relay and Red Indicating Light, door mounted, auto reset | L |
Time Delay Relay Solid State, Multi-Function (on-delay, off-delay, single-shot, recycling) | M |
Phase & Voltage Monitor Protection against Low & High Voltage, Unbalance, Phase Loss & Reversal | N |
Surge/Lightning Arrester | O |
High Water Alarm Beacon Light NEMA type 4X, Top mounted, Red Beacon, Tamper-proof, Halogen Lamp | P |
High Water Alarm Horn NEMA type 4X, Side mounted, 103dB @ 10 Ft., adjustable output, with silenc-ing pushbutton | Q |
High Water Alarm Dry-Contact 1-N.O. Contact for remote monitoring of alarm status | R |
Convenience Receptacle GFCI, 120V, 15 Amp, with weather-proof cover | S |
Intrinsically Safe Relay: Interfaces with on/off floats Note: A separate ISR is required for High or Low Water Alarm | T |
Auxiliary Control Relay | U |
Push-to-Test Pilot Light | V |