Available Options

Options for: Motor Starters & Pump Panels

DescriptionOption Code
Control Circuit Transformer
With Primary & Secondary Protective Fuses
208/240/480 – 120V @ 50VA CT50
208/240/480 – 120V @ 100VA CT100
208/240/480 – 120V @ 150VA CT150
208/240/480 – 120V @ 250VA CT250
208/240/480 – 120V @ 500VA CT500
Interposing Relay
For separate control voltage input ( ** Specify required Voltage when ordering)
IR-**
Time Delay Relay
( ** Specify required function when Ordering) Note: This option requires a control circuit transformer
TD-**
Programmable Time Clock
24 Hour, 7 Day function Note: This option requires a control circuit transformer
TC
Liquid Level Relay
( ** Specify required function when ordering) Note: This option requires a control circuit transformer
LLR-**
Indicating Light
Specify Function and Lens color when ordering (ie: run/red)
PL-**
Electronic Programmable Overload Relay
Protects 3 Phase Motors against: Overload, Underload, High Voltage, Low Voltage, Loss of Phase, Phase Reversal, Phase & Voltage, Unbal-ance, Rapid Cycling, and Ground Fault
Motor Full Load Amps: 2 – 90 Amps DEOL
Motor Full Load Amps: 91 – 600 Amps (includes current transformers) CTEOL
Phase & Voltage Monitor
Protects Three Phase motors against: High Voltage, Low Voltage, Phase Reversal, Loss of Phase, and Unbalance
PMR
Secondary Surge Arrester
Offers a degree of protection against damage due to lightning strikes
LA
Surge Capacitor
Controls surges which are too light or fast for a surge arrester
SC
Low Suction Cut-Off
Option includes a Terminal Block for remote pressure switch, a Red Indicating Light, and a Timing Relay to prevent nuisance tripping Note: This option requires a Control Circuit Transformer
LSC
High Pressure Shutdown
Option includes a Terminal Block for remote pressure switch, a Red Indicating Light, and manual Reset Pushbutton Note: This option requires a Control Circuit Transformer
HPS
Elapsed Hour Meter
Records motor running time in Hours, Non Reset, 99999.9 Hours Note: This option requires a control circuit transformer
ETM
NEMA Type 4 Steel Enclosure
Water & Dust-Tight, Outdoors
N4
NEMA Type 4X Stainless Steel Enclosure
Water & Dust-Tight, Outdoors, Corrosion-Resistant
N4XS
NEMA Type 4X Fiberglass-Reinforced Polyester Enclosure
Water & Dust-Tight, Outdoors, Corrosion-Resistant
N4XF
Starter Auxiliary Contacts
1 N/O & 1N/C contacts interlocked with starter
AUX

Options for: Duplex Booster

DescriptionOption Code
Low Suction Cut-Off
Option includes a terminal block for remote pressure switch, a Red In-dicating Light, and a Timing Relay
LSC
Low Pressure Alarm
Option includes a terminal block for remote pressure switch, a Red In-dicating Light, and a Timing Relay
LSP
High Pressure Shutdown
Option includes a terminal block for remote pressure switch, a Red In-dicating Light, and manual Reset Pushbutton
HPS
Interposing Relay
For use with separate control voltage ( ** Indicate required Voltage when ordering)
IR-**
Time Delay Relay
( ** Indicate required function when Ordering)
TD-**
Programmable Time Clock
24 Hour, 7 Day function
TC
Elapsed Hour Meter
99999.9 Hours, Non Reset Quantity Two
ETM
Cycle Counter
6 Digits, Non Reset Quantity Two
CC
Indicating Light
( ** Indicate Lens color and Function when ordering)
PL-**
Phase & Voltage Monitor
Protects 3-Phase motors against: High Voltage, Low Voltage, Phase Reversal, Loss of Phase, and Unbalance
PMR
Surge/Lightning Arrester
LA
Surge Capacitor
SC
Starter Auxiliary Contacts
Option includes 1-N.O. & 1-N.C. Auxiliary Dry or Powered Contacts for interfacing with remote loads or monitoring Quantity Two Sets (one per starter)
AUX
Electronic Programmable Overload Relay, Motor Saver 777
Protects 3-Phase Motors against: Overload, Underload, High Voltage, Low Voltage, Loss of Phase, Phase Reversal, Phase & Voltage Unbal-ance, Rapid Cycling, and Ground Fault Quantity Two
    Motor Full Load Amps: 2 – 90 Amps
DEOL
External Electric Reset Pushbutton for Motor Saver 777
Quantity Two
EOLR
Deduct for Auto Duplex AlternatorNALT
Terminal Block
3P, 600V, 30 AMPS (Specify Function)
TB

Options for: Duplex Lift Station

DescriptionOption Code
Dead-front Enclosure Construction
Tamper-proof design with Swing-out inner door and Lockable outer door
A
NEMA/UL Type 4 Enclosure
Steel, Water & Dust-Tight, Indoor/Outdoor use
B
NEMA/UL Type 4X
Fiberglass-Reinforced Polyester, Water & Dust-Tight, Indoor/Outdoor use, Corrosion-Resistant
C
NEMA/UL Type 4X
304 Stainless Steel, Water & Dust-Tight, Indoor/Outdoor, Corrosion-Resistant
D
Anti-Condensation Cabinet Heater
100 Watt, Fan-Driven, with integral adjustable thermostat
E
Elapsed Hour Meters
(2) 99999.9 Hours, Non-Reset, door mounted
F
Pump Running Indicating Lights
(2) Green Lens, door mounted
G
Auxiliary Contacts
(2) 1-N.O./1-N.C. for remote monitoring of pump status
H
Motor Seal Failure Indicating Light
(2) Amber Lens, door mounted – Option requires Moisture Detecting Relay
I
Moisture Detecting Relays
(2) Relay Monitors a Seal Failure condition in the motor. Unless otherwise speci-fied, the standard design will not shut-down pump.
J

Options for: Simplex Lift Station

DescriptionOption Code
Dead-front Enclosure Construction
Tamper-proof design with Swing-out inner door and Lockable outer door
A
NEMA/UL Type 4 Enclosure
Steel, Water & Dust-Tight, Indoor/Outdoor use
B
NEMA/UL Type 4X
Fiberglass-Reinforced Polyester, Water & Dust-Tight, Indoor/Outdoor use, Corrosion-Resistant
C
NEMA/UL Type 4X
304 Stainless Steel, Water & Dust-Tight, Indoor/Outdoor, Corrosion-Resistant
D
Anti-Condensation Cabinet Heater
100 Watt, Fan-Driven, with integral adjustable thermostat
E
Elapsed Hour Meter
99999.9 Hours, Non-Reset, door mounted
F
Pump Running Indicating Light
Green Lens, door mounted
G
Auxiliary Contacts
1-N.O./1-N.C. for remote monitoring of pump status
H
Motor Seal Failure Indicating Light
Amber Lens, door mounted – Option requires Moisture Detecting Relay
I
Moisture Detecting Relay
Relay Monitors a Seal Failure condition in the motor. Unless otherwise speci-fied, the standard design will not shut-down pump.
J
Motor Over-Temperature Shutdown
Terminal Block for thermal switch in motor. Motor shutdown with auto reset
K
Motor Over-Temperature Indicating Light
Relay and Red Indicating Light, door mounted, auto reset
L
Time Delay Relay
Solid State, Multi-Function (on-delay, off-delay, single-shot, recycling)
M
Phase & Voltage Monitor
Protection against Low & High Voltage, Unbalance, Phase Loss & Reversal
N
Surge/Lightning Arrester O
High Water Alarm Beacon Light NEMA type 4X, Top mounted, Red Beacon, Tamper-proof, Halogen LampP
High Water Alarm Horn NEMA type 4X, Side mounted, 103dB @ 10 Ft., adjustable output, with silenc-ing pushbuttonQ
High Water Alarm Dry-Contact 1-N.O. Contact for remote monitoring of alarm status R
Convenience Receptacle GFCI, 120V, 15 Amp, with weather-proof coverS
Intrinsically Safe Relay: Interfaces with on/off floats
Note: A separate ISR is required for High or Low Water Alarm
T
Auxiliary Control Relay U
Push-to-Test Pilot LightV